I tried cycling the system at the breaker level on the panel thinking there might be a glitch as well as re seating the cell connector that plugs into the panel.
Goldline aqualogic no cell power 2.
Main pcb layout a i remote dsp comm rs485 10vdc b temp sensor terminal block 5vdc c heater 1 2 terminal block dry contacts d valves 1 4 4amp fuse 24vac e cell plug for chlorination f high voltage relays top filter lights aux1 aux2.
Almost all goldline controls replacement parts have a date code.
The first 2 digits are the year of manufacture the next two the month.
If you get no cell power before doing anything else here s the easiest testing method.
If no voltage is measured continue to step 1b.
My display is saying chlorinator off no cell power and check system no cell power 2.
Please contact tech service.
Plug both wire to the fuse directly.
This must be resolved by a certified technician.
If i re boot it will display correctly for about a minute and then you can feel the cylenoid looking thing clicking and then it will display as mentioned above.
Replace main board pcb.
I called goldline and they said it is probably the main board.
No cell power cell power error low volts stop.
Unplug the yellow fuse from its socket.
Verify that 20 24 volts ac is present between the two yellow wires.
Same with the serial numbers on your cells and control boxes after the 5a 5e 5l 3l and 3e.
G flow monitor flow switch connector h p transformer input 120vac x 2.
908 355 7995 or contact a pool professional.
In diagnostic mode it shows 0v 0a in both positive and negative polarity so something is definitely wrong.
No cell power 1 or no cell power 2 no cell power 1 no cell power 2 go to step 1a page 4.
Turn on the main braker and your goldline.
Please add liquid chlorine to the pool until the issue has been resolved.
If the voltage is ok go to step 1c.
Try starting the filter pump.